Technical reference · English
Functional role
- REOMED ISONET network isolators are used for electrical isolation of equipment in Ethernet networks for copper wire communications.
- Isolation protects equipment and people from possible voltage spikes on the power supply.
- Potential parasitic currents on the network cable shield are reliably prevented.
- Protection in both transmission directions interrupts the shield connection of network cables:
- No additional power supply required
- No software installation required
- maintenance free
- Complies with:
- RoHS standard
- EN 60950-1
- Tested according to EN 60601-1
Electrical properties
| Isolation voltage | 4 kV |
|---|---|
| Input and output connector | RJ45 |
| Supported network protocols | 10BaseT, 100BaseTx, 1000BaseT |
| Insertion loss | -1.3 dB max. |
| Return loss | -8 dB min. |
| protect | IP 20 |
| Maximum voltage for connected equipment | 250 Vac rms |
| operating temperature | -10 ~ +70°C |
| storage temperature | -40 ~ +85°C |
| Humidity | 10 ~ 90% (without condensation) |
| Shell | Plastic sealing |
| weight | 45 grams |
| Dimensions (B×H×T) | 25mm x 66mm x 40mm |
Application method

Industry photograph