UPS systems

ATK-SIPS Multifunctional Integrated Medical Power System

Integrated power, isolation monitoring and power quality

The wall-recessed ATK-SIPS integrates active filtering, reactive power compensation, a 10 kVA online UPS, a 10 kVA medical isolation transformer, online insulation monitoring, fault waveform recording and cloud monitoring for operating-room and ICU critical-power applications.

Medical power showcaseExplore the ATK-SIPS medical power showcaseExplore the system components and application context.
Explore technical details

PRODUCT INSIGHTS

01

Integrated system functions

Active filtering, reactive power compensation, online insulation monitoring, fault waveform recording and cloud monitoring are combined in one wall-recessed unit.

02

Continuous supply and medical isolation

The unit combines a 10 kVA online UPS (9 kW rated active power) with a 10 kVA medical isolation transformer; the stated transfer time is 0 seconds.

03

Filtering and output quality

It uses 4th-order active filtering, with output total harmonic distortion below 3%.

Black server racks, network cables and status lights in a data centerIndustry photograph

BUILT FOR YOUR ENVIRONMENT

Connect the product to your application.

  • Operating-room critical power
  • ICU critical power
Explore application solutions
01 /

Product information

TECHNICAL SPECIFICATIONS

Product specifications & functions

Integrated functions

Active filtering, reactive power compensation, online insulation monitoring, fault waveform recording and cloud monitoring.

Online UPS

Rated capacity: 10 kVA; rated active power: 9 kW; stated mains-to-battery transfer time: 0 seconds and backup time: 30 minutes.

Medical isolation transformer

Rated capacity: 10 kVA; insulation class F; leakage current: 0.1 mA.

Filtering and output quality

4th-order active filtering up to the 50th harmonic; output total harmonic distortion <3%.

Installation format

Wall-recessed integrated unit.

UPS battery

Semi-solid lithium iron phosphate battery with cell-level BMS management.

Reactive-power compensation

Rated compensation: 3 kVAR, automatically switched; power factor after compensation: ≥0.9.

Online insulation monitoring

Active pulse-injection monitoring with a range up to 10 MΩ; 2–3 s response with system leakage capacitance of 5–10 μF.

Operator interface

7-inch touchscreen management terminal with a dynamic status light strip.

Applications

For operating-room and ICU critical-power applications.

Select the model and configuration for your supply system, load and installation conditions. Use the applicable product documentation for installation and operation.